Biostar VP5200SS16 Administrator Guide - Page 72
Con zone inputs, Con alarm actions and outputs
View all Biostar VP5200SS16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
3. Setup the BioStar System 3.5.2.3 Configure zone inputs When adding devices to an alarm or fire alarm zone, you must also configure the zone inputs. To configure inputs: 1. Click Doors in the shortcut pane. 2. In the navigation pane, click the name of a zone. 3. In the Zone tab, at the bottom of the Device List, click Add Input. This will open the Add Zone Input dialog box. 4. Type a name for the input in the Name field. 5. Select a device from the drop-down list. 6. Select one of the available inputs by clicking the checkbox next to the appropriate input. 7. Select the normal position of the input (N/O-normally open or N/C-normally closed). 8. Set the duration (in milliseconds) of the input signal. 9. Click OK to add the input to the Input List. 3.5.2.4 Configure alarm actions and outputs Configure alarm actions to specify what alerts to receive, if any, and which ports and relays to use for alarm outputs. The Alarm tab (in the Zone pane) offers the following options for all zones except access zones. For more information about alarms, see sections 3.5.2.5 and 3.10. Program Sound: Set a sound to be emitted by the software (at the host computer or BioStar Server). To add custom sounds, please see section 3.10.1.2. Device Sound: Set a sound to be emitted by a particular device. 72 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com