Biostar VP5200SS16 Administrator Guide - Page 263
Door Open Period sec
View all Biostar VP5200SS16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 263 highlights
5. Customize Settings IO Device: When using two devices on a single door, specify which device's IO ports will be used. Door Relay: Select a door relay. Exit Button: Select a device input to use for an exit button (Disable or Input 0 and Input 1 for each device added). (Switch Type): Set the normal position of the input used for an exit button (N/O- normally open or N/C-normally closed). Door Status: set an input for a sensor that detects the current status of the door. (Switch Type): Set the normal position of the input used for a door status sensor (N/O- normally open or N/C-normally closed). Door Open Period (sec): Set the duration (in seconds) that a door relay should be activated when a door is opened. After this duration, the relay will stop sending the signal to open the door. The default is three seconds. Door Open Alarm (sec): Set the duration (in seconds) that a door can remain open before an alarm will sound. Driven by: Select types of events that will trigger associated devices to open the door. - All Events (default): Associated devices will open the door on any successful authorization events. - TNA + AUTH: Associated devices will open the door on successful T&A or credential authorization events or T&A authorization events. To use this option, you must select the Use Relay checkbox in the T&A tab. This option is only available for BioStation, BioLite Net, D-Station, X-Station, BioStation T2, and FaceStation devices. For more information about configuring T&A settings, see section 5.1.1.9, 5.1.3.9, 5.1.6.11, 5.1.7.10, and 5.1.8.11. - AUTH: Associated devices will open the door only on successful credential authorization events. - TNA: Associated devices will open the door only on successful T&A authorization events. To use this option, you must select the Use Relay checkbox in the T&A tab. This option is only available for BioStation, BioLite Net, D-Station, X-Station, BioStation T2, and FaceStation devices. For more information about configuring T&A settings, see section 5.1.1.9, 5.1.3.9, 5.1.6.11, 5.1.7.10, and 5.1.8.11. - Disabled: Associated devices will not open the door, regardless of the attempted authorization events. Closed by: Select an option for closing the door. - Open period: The BioStar system will close the door after the period specified in the Door Open Period (sec) field. - Open period+Status: The BioStar system will attempt to close the door based on door status (if you have connected door sensors and the system can detect that the door is open). If door sensors are not connected or the system is unable to detect the door status, the system will close the door after the period specified in the Door Open Period (sec) field. This setting is useful when used with revolving doors, for 263 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com