5. Customize Settings 5.1.9.10 T&A tab The T&A tab allows you to configure the mode and key settings for a FaceStation device. To save changes to time and attendance settings, you must click Apply at the bottom of the tab. You can also apply the same settings to other devices by clicking Apply to Others. T&A Mode: Set the time and attendance mode: - Not Use: Disable the time and attendance functions for this device. - Manual: Users must press the specified key every time they enter or leave to record their T&A events. - Manual Fix: When a T&A key is pressed, the device will remain in that mode until a different T&A key is pressed. - Auto change: The device will automatically change T&A modes to correspond with the functions specified for a time period. - Event Fix: The device will perform only the specified T&A function. T&A Key: Specify which keys to use for T&A events and the event types associated with them: - Function Key: Select a function key from the drop-down list to assign a T&A event (F1-F4, EXT01-EXT12). If you are using the Event Fix mode, you can click the checkbox to the right to designate a fixed event. - Event Caption: Enter a caption for the event. - Auto Mode Schedule: When using the Auto Change mode, you can specify when the event will occur by selecting a timezone in the dropdown list. For more information on creating a timezone, see section 3.7.1. 260 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com