5. Customize Settings - Set Time: Set the time on the device.  Operation Mode: For each of the following options, click the corresponding checkbox to enable Double Verification Mode, which requires verification of two users' credentials to gain entry to a door. - Card Only: Set the device to require only card authorization (Always, Disable, or custom schedule). - Server Matching: Enable this setting to perform card ID matching at the BioStar server, instead of the device. When this mode is enabled, the device will send card ID to the server to verify a match. This mode is useful when you have more users than can be downloaded to a device or user information cannot be distributed due to security concerns.  Mifare - Not use Mifare: Check this box to disable MIFARE card authorization. - Use Data Card: Check this box to use the user data on the MIFARE card for authorization. The user data card does not provide fingerprint templates. - View Mifare Layout: Click this button to view the MIFARE layout used by the device. For more information about configuring MIFARE layouts, please see section 3.6.4.7.  Card ID Format - Format Type: Set the type of pre-processing to occur on card ID data (Normal or Wiegand). If "Normal" is selected, the card ID data will be processed in its original form. If "Wiegand" is selected, devices will interpret card ID data according to the Wiegand format settings. - Byte Order: Specify whether to swap ID card data between cards and devices by most significant byte (MSB) or least significant byte (LSB). - Bit Order: Specify whether to swap ID card data between cards and devices by most significant bit (MSB) or least significant bit (LSB). - In Double mode, setting option which includes an administrator is supported. In Double mode, door relay will not open unless an administrator authenticates within 15 seconds after a user authenticates. If this option is not activated, the door relay will open when other two users, regardless of whether being a user or an administrator, authenticate within 15 seconds. Note: This feature is supported from the FW versions, BioStation 1.93, BioStation T2 1.3, FaceStation 1.3, BioEntry Plus 1.6, BioEntry W 1.2, BioLite Net 1.4, Xpass 1.3.. - Use Wiegand Card Bypass: This feature makes the device to send out Card CSN according to Wiegand setting of BioStar without having to conduct a matching. This is designed to be used as a dummy reader in a connection with a third party access control unit through Wiegand. When a card data input is made, the device sends out the data through Wiegand without going through a matching process. 187 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291

5. Customize Settings
Copyright
©
2014, Suprema Inc. On the web: www.supremainc.com
187
Set Time:
Set the time on the device.
Operation Mode
: For each of the following options, click the corresponding
checkbox to enable Double Verification Mode, which requires verification of
two users
credentials to gain entry to a door.
Card Only:
Set the device to require only card authorization (
Always
,
Disable
, or custom schedule).
Server Matching
: Enable this setting to perform card ID matching at
the BioStar server, instead of the device. When this mode is enabled,
the device will send card ID to the server to verify a match. This mode
is useful when you have more users than can be downloaded to a
device or user information cannot be distributed due to security
concerns.
Mifare
Not use Mifare
: Check this box to disable MIFARE card authorization.
Use Data Card:
Check this box to use the user data on the MIFARE
card for authorization. The user data card does not provide fingerprint
templates.
View Mifare Layout
: Click this button to view the MIFARE layout used
by the device. For more information about configuring MIFARE
layouts, please see section 3.6.4.7.
Card ID Format
Format Type
: Set the type of pre-processing to occur on card ID data
(
Normal
or
Wiegand
). If
Normal
is selected, the card ID data will be
processed in its original form. If
Wiegand
is selected, devices will
interpret card ID data according to the Wiegand format settings.
Byte Order
: Specify whether to swap ID card data between cards and
devices by most significant byte (
MSB
) or least significant byte (
LSB
).
Bit Order:
Specify whether to swap ID card data between cards and
devices by most significant bit (
MSB
) or least significant bit (
LSB
).
In Double mode, setting option which includes an administrator is supported.
In Double mode, door relay will not open unless an administrator
authenticates within 15 seconds after a user authenticates. If this option is
not activated, the door relay will open when other two users, regardless of
whether being a user or an administrator, authenticate within 15 seconds.
Note:
This feature is supported from the FW versions,
BioStation 1.93,
BioStation T2 1.3, FaceStation 1.3, BioEntry Plus 1.6, BioEntry W 1.2, BioLite
Net 1.4,
Xpass 1.3..
Use Wiegand Card Bypass: This feature makes the device to send out Card
CSN according to Wiegand setting of BioStar without having to conduct a
matching. This is designed to be used as a dummy reader in a connection
with a third party access control unit through Wiegand. When a card data
input is made, the device sends out the data through Wiegand without
going through a matching process.