Biostar VP5200SS16 Administrator Guide - Page 70

Add and Con Zones

Page 70 highlights

3. Setup the BioStar System  Muster zone: Use this zone to monitor and track employees during an emergency or to perform a "roll call" where employees are required to be present in a particular area at a particular time. Muster zone allows administrators to determine if any employee has not reported to the muster area and, if any employee is unaccounted for, take the necessary actions to locate them. For more information about customizing muster zone, see section 5.3.6.  Interlock zone: Use this zone to create an interlock area with two doors equipped with devices. When an external input indicates that one door is open, the other door is automatically locked to provide a secure interlock area. A reader-equipped door that does not belong to any other zone can be used to create up to four interlock zones (four zones maximum per reader). For more information about configuring an interlock zone, see section 5.3.7. 3.5.2 Add and Configure Zones When you add a zone, you can use the four tabs in the Zone pane to configure the zone. For an explanation of zone settings, see section 5.3.  Details: Add devices and specify inputs or other parameters for a zone.  Alarm: Specify alarm actions and outputs.  Access Group: Apply access groups to a zone (not available for fire alarm zones).  Event: View events associated with a zone. 3.5.2.1 Add a zone To add a new zone: 1. Click Doors in the shortcut pane. 2. In the navigation pane, right-click Zone. 3. Click Add Zone. 4. Type a name for the zone in the Name field. 5. Select a zone type from the drop-down list (see section 3.5.1 for zone descriptions). 6. Press OK. The Zone pane will appear on the right side of the screen. 70 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291

3. Setup the BioStar System
Copyright
©
2014, Suprema Inc. On the web: www.supremainc.com
70
Muster zone
: Use this zone to monitor and track employees during an emergency or to
perform a
roll call
where employees are required to be present in a particular area at a
particular time. Muster zone allows administrators to determine if any employee has not
reported to the muster area and, if any employee is unaccounted for, take the necessary
actions to locate them. For more information about customizing muster zone, see
section 5.3.6.
Interlock zone
: Use this zone to create an interlock area with two doors equipped with
devices. When an external input indicates that one door is open, the other door is
automatically locked to provide a secure interlock area. A reader-equipped door that
does not belong to any other zone can be used to create up to four interlock zones
(four zones maximum per reader). For more information about configuring an interlock
zone, see section 5.3.7.
3.5.2
Add and Configure Zones
When you add a zone, you can use the four tabs in the Zone pane to configure the zone. For
an explanation of zone settings, see section 5.3.
Details:
Add devices and specify inputs or other parameters for a zone.
Alarm
: Specify alarm actions and outputs.
Access Group
: Apply access groups to a zone (not available for fire alarm zones).
Event
: View events associated with a zone.
3.5.2.1
Add a zone
To add a new zone:
1.
Click
Doors
in the shortcut pane.
2.
In the navigation pane, right-click
Zone
.
3.
Click
Add Zone
.
4.
Type a name for the zone in the Name field.
5.
Select a zone type from the drop-down list (see section 3.5.1 for zone
descriptions).
6.
Press
OK
. The Zone pane will appear on the right side of the screen.