Change Wiegand Formats
View all Biostar VP5200SS16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
3. Setup the BioStar System Output: Use this tab to add, modify, or delete output settings for the device. Display/Sound: Use this tab to adjust display or sound settings and add background images and sounds. T&A: Use this tab to configure time and attendance settings. Wiegand: Use this tab to configure the Wiegand format. For more information about Wiegand formats, see section 3.2.133. 4. When you are finished configuring the device, click Apply to save your changes. 5. To apply the same settings to other devices, click Apply to Others and select other devices from the Device Tree dialog box. 3.2.13 Change Wiegand Formats From the BioStar interface, you can configure the Wiegand format of a device to control device inputs and outputs. To configure the Wiegand format: 1. Click Device in the shortcut pane. 2. In the navigation pane, click a device name. 3. Click the Wiegand tab in the Device pane. 4. Click Change Format. This will open the Wiegand Configuration wizard. 5. Click a radio button to select one of the following formats: 26-bit Standard: This format is the most widely used and consists of an 8-bit FC code and a 16-bit ID. You cannot change the bit definition of the format or the parity bits of this format. 59 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com