Biostar VP5200SS16 Administrator Guide - Page 74
Con external input/output settings
View all Biostar VP5200SS16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
3. Setup the BioStar System 3.5.2.6 Configure external input/output settings Instead of manually arming or disarming alarm zones, you can configure the BioStar system to automatically determine when to arm or disarm alarm zones based on the status of a specified input. You can also prevent the BioStar system from arming an alarm zone when a monitored input is in a not-ready position. Finally, you can configure the system to send a specified signal to an external output when it arms or disarms alarm zones. External input/output settings are available in BioStation V1.8, BioEntry Plus V1.4, BioEntry W V1.0, BioLite Net V1.2, Xpass and Xpass Slim V1.0, D-Station V1.0, X-Station V1.0, BioStation T2 and FaceStation V1.0 or higher. To configure external input/output settings: 1. Click Doors in the shortcut pane. 2. In the navigation pane, click the name of an alarm zone. 3. Click the Details tab in the Zone pane. 4. Click Setup to the right of External Input/Out. This will open the External I/O Setting dialog box. 5. Configure the following input/output settings as desired: To prevent the BioStar system from arming an alarm zone: a. Under External Sensor Status, select a device from the Device drop-down list. b. Select an input from the Input drop-down list. c. Select the position of the input (N/O - normally open or N/C - normally closed) that will prevent the system from arming the alarm zone. To allow the BioStar system to automatically arm or disarm an alarm zone: 74 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com