Biostar VP5200SS16 Administrator Guide - Page 181
Output tab
View all Biostar VP5200SS16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 181 highlights
5. Customize Settings BioStation T2 (FW 1.3v), FaceStation (FW 1.3v), BioEntry Plus (FW 1.6v), BioEntry W (FW 1.2v), BioLite Net (FW 1.4v), and Xpass (FW 1.3v). Schedule: Set the schedule for the input actions (Always, Disable, or custom schedule). Duration (ms): Set the duration (in milliseconds) an input signal must last to trigger the specified action. 5.1.3.6 Output tab The Output tab lists output settings you have specified for a BioLite Net device. Buttons at the bottom of the tab allow you to add, modify, or delete output settings. To add or modify settings, you must specify them from the Output Setting dialog box. For more information about configuring output settings, see section 3.10.3.1. Device Type: Select the device type for which you will add or modify settings. Port: Select an output port (Relay 0). For Secure I/O devices, these settings are available: Relay 0 or Relay 1. Alarm On Event: Specify settings and click Add to add the event to the Alarm On Event list. These events will activate an alarm. - Event: Select an event that will activate an alarm (Auth Success, Auth Fail, Auth Duress, Anti-passback Fail, Access Not Granted, Entrance Limited, Admin Auth Success, Tamper On, Door Opened, Door Close, Forced Open Door, Held Open Door, or Detect Input #1-3). - Device: Select the device to monitor for an alarm event. 181 Copyright ©2014, Suprema Inc. On the web: www.supremainc.com