Epson 2200 Service Manual - Page 116

Overview, Precautions, EPSON Stylus PHOTO 2100/2200, Revision B, DISASSEMBLY AND ASSEMBLY

Page 116 highlights

EPSON Stylus PHOTO 2100/2200 Revision B 4.1 Overview This chapter describes procedures for disassembling and assembling this product. Unless otherwise specified, the disassembled units or main components can be reassembled by reversing the disassembling procedure. • Warning Procedures that could result in injury or loss of life, if cautions are not taken, are described under the heading "WARNING". • Caution Precautions for any disassembly or assembly procedures are described under the heading "CAUTION". • Check Point Tips for disassembling procedures are described under the heading "CHECK POINT". • Reassembly If the assembling procedure is different from the reverse procedure of disassembling, it is described under the heading "REASSEMBLY". • Adjust Any adjustments required after disassembling or assembling are described under the heading "ADJUST". When you need to disassemble any units or parts that are not described in this chapter, refer to the exploded diagrams in the Appendix. Before starting your work, always read the precautions described in the next section. 4.1.1 Precautions Before starting the disassembling/reassembling work of this product, always read the descriptions under the following headings "WARNING" and "CAUTION" carefully. W A R N IN G " Before starting the disassembling/reassembling work of this product, always disconnect the power cable. However, if you cannot disconnect the power cable for voltage measurement or like, be extremely careful not to get an electric shock and follow the procedures in this manual to do your work. " Always wear goggles to protect your eyes from ink. If ink gets in your eyes, wash your eyes with clean water and see the doctor. " To prevent injury from sharp metal edges, always wear gloves for disassembly and reassembly. " If ink has adhered to your skin, wash it with soap and water. If it has caused skin irritation, see the doctor. " To protect the microprocessors and circuitry, use static discharge equipment, such as anti-static wrist straps, and handle them carefully when accessing the internal components. W A R N IN G " Avant de commencer, assurez vous que l'imprimante soit eteinte et que le cordon d'alimentation soit debranche. " Veillez a jeter les piles usagees selon le reglement local. DISASSEMBLY AND ASSEMBLY Overview 116

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258

EPSON Stylus PHOTO 2100/2200
Revision B
DISASSEMBLY AND ASSEMBLY
Overview
116
4.1
Overview
This chapter describes procedures for disassembling and assembling this product.
Unless otherwise specified, the disassembled units or main components can be
reassembled by reversing the disassembling procedure.
Warning
Procedures that could result in injury or loss of life, if cautions are not taken, are
described under the heading "WARNING".
Caution
Precautions for any disassembly or assembly procedures are described under the
heading "CAUTION".
Check Point
Tips for disassembling procedures are described under the heading "CHECK
POINT".
Reassembly
If the assembling procedure is different from the reverse procedure of
disassembling, it is described under the heading "REASSEMBLY".
Adjust
Any adjustments required after disassembling or assembling are described under the
heading "ADJUST".
When you need to disassemble any units or parts that are not described in this chapter,
refer to the exploded diagrams in the Appendix.
Before starting your work, always read the precautions described in the next section.
4.1.1
Precautions
Before starting the disassembling/reassembling work of this product, always read the
descriptions under the following headings "WARNING" and "CAUTION" carefully.
W
A
R
N
I
N
G
"
Before starting the disassembling/reassembling work of this
product, always disconnect the power cable. However, if you
cannot disconnect the power cable for voltage measurement or
like, be extremely careful not to get an electric shock and follow
the procedures in this manual to do your work.
"
Always wear goggles to protect your eyes from ink. If ink gets in
your eyes, wash your eyes with clean water and see the doctor.
"
To prevent injury from sharp metal edges, always wear gloves
for disassembly and reassembly.
"
If ink has adhered to your skin, wash it with soap and water. If it
has caused skin irritation, see the doctor.
"
To protect the microprocessors and circuitry, use static
discharge equipment, such as anti-static wrist straps, and handle
them carefully when accessing the internal components.
W
A
R
N
I
N
G
"
Avant de commencer, assurez vous que l’imprimante soit
eteinte et que le cordon d’alimentation soit debranche.
"
Veillez a jeter les piles usagees selon le reglement local.