Epson 2200 Service Manual - Page 182
Disassembling the Cutter Unit
UPC - 010343841840
View all Epson 2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 182 highlights
EPSON Stylus PHOTO 2100/2200 Revision B " When reinstalling the PF Roller Support, hitch the two upper hooks on the projections of the Under Frame, and insert the two lower hooks into the notches. Refer to Figure 4-137, "Removing the PF Roller Support". " Place the Under Driven Roller on the joggle of the PF Roller Support in advance. Refer to Figure 4-137, "Removing the PF Roller Support". 4.2.18 Disassembling the Cutter Unit 4.2.18.1 Removing the Cutter Sensor 1. Remove the two screws 15) C.B.S 3×8 (9±1kgf.cm), two screws 6) C.B.S 3×6 (9±1kgf.cm) and two screws (T.B.D) that secure the Cutter Housing. 2. Release the three hooks located on the Cutter Unit bottom. C.B.S 3x8 Screws T.B.D Cutter Housing C.B.S 3x6 Hooks Figure 4-138. Screws That Secure the Cutter Housing DISASSEMBLY AND ASSEMBLY Disassembly 182