Occurrence Timing, Phenomenon Detail, Faulty Part/Part, Check Point, Remedy, Using a tester
UPC - 010343841840
View all Epson 2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
EPSON Stylus PHOTO 2100/2200 Revision B Table 3-17. Phenomenon-Based Fatal Error Check Points Occurrence Timing Phenomenon Detail Faulty Part/Part Name Check Point Remedy At power-on The power-on sequence is executed but Fatal error is displayed. PF drive system 1. Check B9 of the EEPROM to confirm that 79 is at 6C. 1. If the value is as in Check point 2, change the PF motor for a new one. At power-on, the PF motor does not operate at all. PF motor 1. Check that the PF motor connector cable is connected to CN16 1. Connect the PF motor connector cable to on the Main board correctly. CN16 on the Main board correctly. PF motor 2. Using a tester, check that the resistance of the PF motor is 23.0Ω ± 25%. 3. Check the PF motor connector cable for damage. 2. If the resistance value is abnormal, change the PF motor for a new one. 3. Change the PF motor for a new one. TROUBLESHOOTING Troubleshooting 97