Epson 2200 Service Manual - Page 169
Removing the CR Motor, Installing the CR Motor, Checking the Ferrite Core
![]() |
UPC - 010343841840
View all Epson 2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
EPSON Stylus PHOTO 2100/2200 8. Remove the two screws 13) C.P.S 3×6 (6±1kgf.cm) that secure the CR Motor, and remove the CR Motor from the Upper Frame. C.P.S 3×6 Revision B " When changing the CR Motor, make sure that the Ferrite Core is fitted to the Cable securely. Ferrite Core CR Motor Figure 4-107. Removing the CR Motor " When reinstalling the CR Motor, face the label of the CR Motor rightward as seen from the printer rear. Refer to Figure 4-108, "Installing the CR Motor". Figure 4-109. Checking the Ferrite Core A D JU S TM E N T R E Q U IR E D " When changing the CR Motor, the following adjustments are necessary. Make the adjustments in the following order. 1. CR tooth skip prevention mechanism adjustment 2. CR motor drive torque dispersion measurement (maximum correction value input) " Refer to "Chapter 5 Adjustment" for the adjustment procedures. Label Figure 4-108. Installing the CR Motor " After installing the CR Motor, fully use care not to damage the tooth surface of the Pinion Gear. Refer to Figure 4-107, "Removing the CR Motor". DISASSEMBLY AND ASSEMBLY Disassembly 169
![](/manual_guide/products/epson-2200-service-manual-fb9e030/169.png)