Icom IC-R9500 Instruction Manual - Page 100

Memory bank set

Page 100 highlights

7 MEMORY OPERATION D Memory bank set [F-6•EDT/BANK] [F-1•Y] [F-2•Z] [F-4•DEF] [EXIT/SET] Main dial Setting bank limit function for memory channel selection, for memory scan can be set in bank set mode or programming bank name. q Select memory list screen as described at previous page. w Push and hold [F-6•EDT/BANK] for 1 sec. to display the memory bank set mode. e Push [F-1•Y] or [F-2•Z] to select the desired item. r Rotate the main dial to set the desired setting. • Push and hold [F-4•DEF] for 1 sec. to select a default value. t Push [EXIT/SET] to return to memory list screen. BANK (Memory Channels) ON Selects the bank limit function for memory channel selection from ON and OFF. (default: ON) BANK (Memory Scan) ON Selects the bank limit function for memory scan from ON and OFF. (default: ON) • Programming bank names [ABC]/[abc] [123]/[Symbol] Keypad [F-1•Ω] [F-2•≈] [F-3•DEL] [F-4•SPACE] Capital letters, small letters, numerals, some symbols and spaces can be used for bank name programming. q Push [F-1•Y] or [F-2•Z] to select the desired memory bank. w Push [F-5•EDIT] to edit memory bank name. • A cursor appears and blinks. e Input the desired character by rotating the main dial or by editing the keypad for number input. • Push [ABC] or [abc] to toggle capital and small letters. • Push [123] or [Symbol] to toggle numerals and symbols. • Push [F-1•Ω] or [F-2•≈] for cursor movement. • Push [F-3•DEL] to delete the selected character. • Push [F-4•SPACE] to input a space. • Using the receiver's keypad, [0]-[9], can also enter numerals. r Push [EXIT/SET] to input and set the name. • The cursor disappears. t Repeat steps q to r to program another memory bank's name, if desired. y Push [EXIT/SET] to return to memory list screen. 7-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

7-8
7
MEMORY OPERATION
D
Memory bank set
Setting bank limit function for memory channel selec-
tion, for memory scan can be set in bank set mode or
programming bank name.
q
Select memory list screen as described at previous
page.
w
Push and hold [F-6•EDT/BANK] for 1 sec. to display
the memory bank set mode.
e
Push [F-1•
Y
] or [F-2•
Z
] to select the desired item.
r
Rotate the main dial to set the desired setting.
• Push and hold [F-4•DEF] for 1 sec. to select a default
value.
t
Push [EXIT/SET] to return to memory list screen.
Main dial
[F-1•
Y
] [F-2•
Z
]
[EXIT/SET]
[F-6•EDT/BANK]
[F-4•DEF]
Selects the bank limit function for memory channel
selection from ON and OFF. (default: ON)
BANK
(Memory Channels)
ON
Selects the bank limit function for memory scan from
ON and OFF. (default: ON)
BANK
(Memory Scan)
ON
• Programming bank names
Capital letters, small letters, numerals, some symbols
(! # $ % & ¥ ? " ’ ` ^ + –
/ . , : ; = < > ( ) [ ] { } | _
~
@)
and spaces can be used for bank name programming.
q
Push [F-1•
Y
] or [F-2•
Z
] to select the desired mem-
ory bank.
w
Push [F-5•EDIT] to edit memory bank name.
• A cursor appears and blinks.
e
Input the desired character by rotating the main dial
or by editing the keypad for number input.
• Push [ABC] or [abc] to toggle capital and small letters.
• Push [123] or [Symbol] to toggle numerals and symbols.
• Push [F-1•
] or [F-2•
] for cursor movement.
• Push [F-3•DEL] to delete the selected character.
• Push [F-4•SPACE] to input a space.
• Using the receiver’s keypad, [0]–[9], can also enter nu-
merals.
r
Push [EXIT/SET] to input and set the name.
• The cursor disappears.
t
Repeat steps
q
to
r
to program another memory
bank’s name, if desired.
y
Push [EXIT/SET] to return to memory list screen.
[F-1•
] [F-2•
]
[F-4•SPACE]
[F-3•DEL]
Keypad
[ABC]/[abc]
[123]/[Symbol]