Mode select memory scan operation
View all Icom IC-R9500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
8 SCANS D Mode select memory scan operation [SQUELCH] [EXIT/SET] [MODE] Scan indicator appears To operate memory scan in a specific mode (ignoring other modes), the mode select memory scan is available. q Push [EXIT/SET] several times to close a multifunction screen, if necessary. w Set the [SQUELCH] control open or closed. • See page 8-3 for squelch condition. e Select the desired operating mode. • The operating mode can also be changed while scanning. rPush [MODE] to start the mode select memory scan. • Scan screen appears and memory mode is selected automatically. • " MODE SELECT MEMORY SCAN " and decimal points blink during mode select memory scan. t When the scan detects a signal, the scan stops, pauses or ignores it depending on the resume setting and the squelch condition. y To cancel the scan, push [MODE]. • Pushing [F5•STOP] also cancels the scan. • Pushing [EXIT/SET] closes the scan screen. 2 or more memory channels with same operating mode must be programmed for mode select memory scan to start. 8-14