11 SET MODE ■ Others set mode (continued) CI-V Baud Rate Sets the CI-V data transfer rate. 300, 1200, 4800, 9600, 19200 bps and "Auto" are available. (default: Auto) When "Auto" is selected, the baud rate is automatically set according to the data rate of connected controller. Auto CI-V Address To distinguish equipment, each CI-V transceiver or receiver has its own Icom standard address in hexadecimal code. The IC-R9500's address is 72h. When 2 or more IC-R9500's are connected to an optional CT-17 CI-V LEVEL CONVERTER, rotate the main dial to select a different address for each IC-R9500; the range is 01h to 7Fh. 72h CI-V Transceive ON Transceive operation is possible with the IC-R9500 connected to other Icom transceivers or receivers. When "ON" is selected, changing the frequency, operating mode, etc. on the IC-R9500 automatically changes those of connected transceivers (or receivers) and vice versa. RS-232C Function Select [RS-232C] connector output data format from CI-V and Decode. CI-V • CI-V : Outputs data in CI-V format. (default) • Decode : Outputs decoded contents in ASCII code format. Decode Baud Rate Selects data transmission speed (Baud rate) when "Decode" is selected in "RS-232C Function" above; settings are 300, 1200, 4800, 9600 and 19200 bps. (default: 9600) 9600 Keyboard Type Selects the connected keyboard type from Japanese, English, United Kingdom, French, French (Canadian), German, Portuguese, Portuguese (Brazilian), Spanish, Spanish (Latin American) and Italian. (default: English) English 11-14