Icom IC-R9500 Instruction Manual - Page 64
Operating P25 Requires optional UT-122
View all Icom IC-R9500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
4 RECEIVE MODES ■ Operating P25 (Requires optional UT-122) [RX] indicator Keypad q Edit the desired frequency using the keypad. w Push [DIGITAL] to select P25. • " P 2 5 " indicator appears. e Rotate the main dial to tune the desired frequency. • [RX] indicator lights green and the S-meter indicates re- ceived signal strength when signal is received. r Rotate [AF] to set audio to a comfortable listening level. [AF] [DIGITAL] Main dial Appears D Convenient functions for P25 • Preamp (p. 5-9) ➥ Push [P.AMP] several times to set the preamp OFF, preamp 1 ON or preamp 2 ON. Only ON/OFF is available above 30 MHz. • "P.AMP1" or "P.AMP2" appears when the preamp 1 or preamp 2 is ON below 30 MHz. "P.AMP ON" appears above 30 MHz. • Attenuator (p. 5-9) ➥ Push [ATT] several times to set the attenuator in 6 dB steps for HF bands, or 10 dB step for 30-1150 MHz. Only 20 dB is available for 1150-3335 MHz. • "ATT" and attenuation level appear when the attenu- ator is ON. • Twin PBT (passband tuning) (p. 5-11) ➥ Rotate [TWIN PBT] controls (inner/outer). • Push [PBT CLEAR] to clear the settings. 4-18