Accessory connector information - specifications
View all Icom IC-R9500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
2 INSTALLATION AND CONNECTIONS ■ Accessory connector information ACC 76 381 54 2 PIN No. NAME DESCRIPTION SPECIFICATIONS 1 ANTS Outputs 5 V when the [ANTENNA] Output current : Less than 100 µA switch is ON. Output impedance : 10 kΩ 2 GND Connects to ground. 3 SEND When grounded, attenuator activates GROUND level : -0.5 to +0.8 V and then audio is muted. Input current : Less than 20 mA 4 NC No connection 5 AF AF detector output. Output impedance : 47 kΩ Fixed, regardless of [AF] position in Output level : 100-300 mV rms default settings. (see notes below) 6 SQLS Squelch output. Squelch open : Less than 0.3 V/5 mA Goes to ground when squelch opens. Squelch closed : More than 6.0 V/100 µA 7 13.8 V 13.8 V output when power is ON. Output current : 100 mA 8 MOUT Output S-meter level. Output voltage : 0 to approx. 4 V Output impedance : 10 kΩ DATA IN 76 381 54 2 PIN No. NAME 1 DATA - IN DESCRIPTION 2 GND Connects to video ground. 3 VIDEO Video signal output. (NTSC system only) 4 GND - 5 NC No connection 6 DATA - OUT 7, 8 NC No connection SPECIFICATIONS Output level : 1 V p-p ±0.2 V Output impedance : 75 Ω NOTE: If the beep level limit is in use, the beep tone decreases from the fixed level when the [AF] control is rotated above a specified level. (p. 11-6) 2-12