HP Workstation x2000 hp workstation x2000 - Technical Reference and Troublesho - Page 103
Run-Time Errors
View all HP Workstation x2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
Tests and Error Messages POST Sequence and POST Error Run-Time Errors During the normal usage of the Workstation (and at boot), MaxiLife continually monitors vital system parameters. These include: temperature errors, fan malfunctions, power voltage drops and CPU problems. Test During normal usage, HP MaxiLife continually checks vital system parameters. If an error occurs, a message appears on the LCD panel. Error Code Action to Take System FAN PCI FAN CPU 1 FAN CPU 2 FAN Processor temperature CPU temperature PCI temperature Disk temperature PSU 12 V error Power CPU error PSU 3V3 error PSU 2V5 error PSU 1V8 error PSU -5V error System or chassis fan, fan cable PCI fan, fan cable CPU 1 fan, fan cable CPU 2 fan, fan cable Processor temperature > 85˚C Thermal or internal processor failure Ambient or PCI temperature > 64˚C Disk temperature > 58˚C, or sensor unplugged Power supply unit failed. Try the following: • Replace the power supply unit with a known working one • If the problem persists, replace the system board Chapter 4 103