HP Workstation x2000 hp workstation x2000 - Technical Reference and Troublesho - Page 99
Possible Error Messages, Preboot Diagnostics Error
View all HP Workstation x2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Figure 4-1 Tests and Error Messages MaxiLife Test Sequence and Error Messages The preboot diagnostic tests run in order of priority, according to their importance to computer functions. On the HP x2000 Workstation, the first detected error displays a message on the LCD status panel. If an error occurs, one of the following screens displays. Possible Error Messages Presence of processor, or processor terminator Control of some voltages: 12V, 3.3V, 1.8V, 2.5V, -5V ERROR CPU Socket ERROR Power Supply Missing or incorrectly installed processor or processor If a power supply error occurs, a cause could reside in the power supply cabling or circuits Figure 4-2 shows how the preboot diagnostics work when an error occurs. Figure 4-2 Preboot Diagnostics Error Vcc State (5V) MaxiLife Firmware CPU or Voltage 12V, 3.3V, 1.8V, Voltage CPU1, CPU2 I2C Bus Hardware Monitoring Temperature Sensors System Memo LCD Status Panel ERROR CPU Socket An error has been detected when checking the processor and processor terminator. The displayed error message could indicate a missing processor or processor terminator. Chapter 4 99