ProSafe Managed Switch logging email message-type subject This command configures the subject line of the email for the specified type. Default Format Mode For urgent messages: Urgent Log Messages For non-urgent messages: Non Urgent Log Messages logging email message-type {urgent |non-urgent |both} subject Global Config no logging email message-type subject This command removes the configured email subject for the specified message type and restores it to the default email subject. Format Mode no logging email message-type {urgent |non-urgent |both} subject Global Config logging email logtime This command configures how frequently non-urgent email messages are sent. Non-urgent messages are collected and sent in a batch email at the specified interval. The valid range is every 30- 1440 minutes. Default Format Mode 30 minutes logging email logtime Global Config no logging email logtime This command resets the non-urgent log time to the default value. Format Mode no logging email logtime Global Config logging traps This command sets the severity at which SNMP traps are logged and sent in an email. Specify the severitylevel value as either an integer from 0 to 7 or symbolically through one of the following keywords: emergency (0), alert (1), critical (2), error (3), warning (4), notice (5), info (6), or debug (7). Default Format Mode Info (6) messages and higher are logged. logging traps Global Config Utility Commands 558