HP Visualize J5000 hp Visualize J5000, J7000 workstations owner's guide (a4978 - Page 131

Ultra2 Wide Low-Voltage Differential SCSI Bus, Length, SCSI Bus Length Constraints

Page 131 highlights

NOTE SCSI Connections SCSI Bus Length Constraints Ultra2 Wide Low-Voltage Differential SCSI Bus Length The maximum cable length for an Ultra2 Wide Low-Voltage Differential SCSI bus is 12 meters. The HP VISUALIZE J5000/J7000 system uses 1 meter of this maximum cable length internally. This means that up to 11 meters of cable can be used for connecting external Ultra2 Wide Low-Voltage Differential SCSI devices to this workstation. When calculating the total Ultra2 Wide Low-Voltage Differential SCSI cable/bus/trace length used externally, remember to account for cables connecting external devices together as well as the bus length internal to those devices. WARNING Do not attach FWD SCSI devices to the LVD SCSI port, or damage will occur. Chapter 7 131

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Chapter 7
131
SCSI Connections
SCSI Bus Length Constraints
Ultra2 Wide Low-Voltage Differential SCSI Bus
Length
The maximum cable length for an Ultra2 Wide Low-Voltage Differential
SCSI bus is 12 meters. The HP V
ISUALIZE
J5000/J7000 system uses 1
meter of this maximum cable length internally. This means that up to 11
meters
of
cable
can
be
used
for
connecting
external
Ultra2
Wide
Low-Voltage Differential SCSI devices to this workstation.
NOTE
When calculating the total Ultra2 Wide Low-Voltage Differential SCSI
cable/bus/trace length used externally, remember to account for cables
connecting external devices together as well as the bus length internal to
those devices.
WARNING
Do
not
attach FWD SCSI devices to the LVD SCSI port, or
damage will occur.