D-Link DXS-3610 User Manual - Page 677
IPv4 Trace Route Result, Source IPv4 Address
![]() |
View all D-Link DXS-3610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 677 highlights
DXS-3610 Series Layer 3 Stackable 10GbE Managed Switch Web UI Reference Guide Parameter ToS Frequency Source IPv4 Address Probe Number Description Enter the ToS value here. This specifies the ToS to be set in the IP header of the outgoing datagram. The range is from 0 to 255. Enter the frequency time for the trace route here. The range is from 0 to 86400. Enter the source IPv4 address here. The specified IPv4 address must one of the IPv4 addresses configured for the Switch. Enter the probe time number here. The range is from 1 to 1000. If unspecified, the default value is 1. Click the Start button to initiate the route trace for each individual section. The fields that can be configured in IPv6 Trace Route are described below: Parameter VRF Name IPv6 Address Domain Name Initial TTL Max TTL Port Timeout Length Frequency Source IPv6 Address Probe Number Description Enter the name of the VRF instance here. This name can be up to 12 characters long. Select and enter the IPv6 address of the destination here. Select and enter the domain name of the destination here. Enter the initial TTL value here. The range is from 1 to 255. Enter the TTL value of the trace route request here. This is the maximum number of routers that a trace route packet can pass. The trace route option will cross while seeking the network path between two devices. The range for the TTL is 1 to 255 hops. Enter the port number here. The value range is from 1 to 65535. Enter the timeout period while waiting for a response from the remote device here. A value of 1 to 65535 seconds can be specified. The default is 5 seconds. Enter the length value here. This specifies the number of bytes of the outgoing datagram. The range is from 1 to 1420 bytes. Enter the frequency time for the trace route here. The range is from 0 to 86400. Enter the source IPv6 address here. The specified IPv6 address must one of the IPv6 addresses configured for the Switch. Enter the probe time number here. The range is from 1 to 1000. If unspecified, the default value is 1. Click the Start button to initiate the route trace for each individual section. After clicking the Start button in IPv4 Trace Route section, the following IPv4 Trace Route Result will appear: Figure 16-33 IPv4 Trace Route Result Window 666
![](/manual_guide/products/dlink-dxs3610-user-manual-7b2fc93/677.png)