BL-1037 7 BL-1037 Message , [BL-1037], ,, CRITICAL, , Faulting chip in slot = , miniS = ,port = due to BE/BI port fault. Probable Cause Indicates a fault on the chip and that all ports on the chip have been disabled. Recommended No action is required. Action Severity CRITICAL BL-1038 Message , [BL-1038], ,, CRITICAL, , Inconsistent FPGA image version detected, please restart the switch for recovery. Probable Cause Indicates that the FPGA image version is incompatible with the software version. Recommended Restart the switch. If the message persists, replace the switch. Action Severity CRITICAL BL-1039 Message , [BL-1039], ,, CRITICAL, , Inconsistent FPGA image version detected, faulting the blade in slot . Probable Cause Indicates that the FPGA image version is incompatible with the software version. Recommended Power cycle the blade. If the message persists, replace the blade. Action Severity CRITICAL Fabric OS Message Reference 71 53-1001338-01