HP StorageWorks 1606 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 705
Xtun-2001, Xtun-2002, Xtun-2003, Xtun-2004
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 705 highlights
10 XTUN-2001 Recommended No action is required. Action Severity INFO XTUN-2001 Message , [XTUN-2001], ,, ERROR, , FCIP Tunnel DOWN . Probable Cause Indicates that the specified tunnel has gone down. Recommended If the tunnel has not been administratively disabled or deleted, a possible network error or Action disruption has occurred. Severity ERROR XTUN-2002 Message , [XTUN-2002], ,, INFO, , FCIP Tunnel Circuit UP. Probable Cause Indicates that the specified circuit is up. Recommended No action is required. Action Severity INFO XTUN-2003 Message , [XTUN-2003], ,, ERROR, , FCIP Tunnel Circuit DOWN . Probable Cause Indicates that the specified circuit has gone down. The tunnel will also be down if this is the last circuit available. Recommended If the tunnel or circuit has not been administratively disabled or deleted, a possible network error or Action disruption has occurred. Severity ERROR XTUN-2004 Message Probable Cause , [XTUN-2004], ,, INFO, , FCIP Tunnel Pri QoS UP. Indicates that the specified quality of service for this tunnel is up. This applies to the data classes only. When the f-class comes online, the tunnel itself is marked as up. Fabric OS Message Reference 635 53-1001338-01