HP StorageWorks 1606 Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01 - Page 157
TABLE 8, System Services Settings, Portlog Events Enable/Disable Settings, Application Attributes
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 157 highlights
configure 2 Descriptions of the Arbitrated Loop Parameter fields are as follows: Send FAN frames? Specifies that fabric address notification (FAN) frames be sent to public loop devices to notify them of their node ID and address. When set to 1, frames are sent; when set to 0, frames are not sent. Enable CLOSE on OPEN received? If this is set, a CLS is returned immediately to an OPN if no buffers are available. This is required for TachLite. Always send RSCN? Following the completion of loop initialization, a remote state change notification (RSCN) is issued when FL_Ports detect the presence of new devices or the absence of pre-existing devices. When set to 1, an RSCN is issued upon completion of loop initialization, regardless of the presence or absence of new or pre-existing devices. System Services Settings Settings affecting System Services are described in Table 8. TABLE 8 Disable RLS probing Field Type Default Range Disable RLS probing Boolean off off or on Disable RLS probing Enables or disables the read link status (RLS) probing. Performed by the FCP daemon, RLS probing reads the link error block from the device. This extended link services command is defined by the FC standards. Refer to the FC standards for information. This parameter is enabled ("on") by default; "off" disables RLS probing. Portlog Events Enable/Disable Settings These settings determine whether or not various types of port events are logged. Each event type displayed on the screen is enabled by default ("on"). When disabled, this event is not logged by the port log. Application Attributes Table 9 lists configurable application attributes. By default, all application attributes are enabled. TABLE 9 Configurable application attributes Application File Type Default Range ssl rpcd Webtools Certificate File CA Certificate File Length of crypto key Secure RPCd Callback secret Basic User Enabled Perform License Checking and Warning Allow Fabric Event Collection Login Session Timeout (in seconds) string string number string boolean boolean boolean number not set not set 128 none no yes yes 7200 varies varies 40, 56, 128 varies no/yes yes/no yes/no 60 to 432000 Fabric OS Command Reference 127 53-1001337-01