HP StorageWorks 1606 Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01 - Page 752
portShow, To display QoS Mappings, To display Byte Streaming parameters
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 752 highlights
2 portShow IKE Policy 1 IPSec Policy 1 Pre-Shared Key testingFIPSandIPSec To display QoS Mappings: switch:admin> portshow fciptunnel 9/ge0 0 -qosmap Slot: 9 Port: ge0 Tunnel ID 0 Tunnel Description "This is a test Description of this tunnel" Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:39:d4:5a Compression on Fastwrite on Tape Pipelining on Uncommitted bandwidth, minimum of 1000 Kbps (0.001000 Gbps) SACK on Min Retransmit Time 100 Keepalive Timeout 90 Max Retransmissions 9 VC QoS Mapping off DSCP Marking (Control): 10, DSCP Marking (Data): 62 VLAN Tagging Id 1062, L2CoS (Control): 1, L2CoS (data): 0 Connected Count: 1 Uptime 2 hours, 14 minutes, 47 seconds IKE Policy 1 IPSec Policy 1 Pre-Shared Key testingFIPSandIPSec VC QoS Map: VC DSCP L2CoS VC DSCP L2CoS VC DSCP L2CoS VC DSCP L2CoS 0 46 7 1 07 0 2 11 3 3 15 3 4 19 3 5 23 3 6 27 0 7 31 0 8 35 0 9 39 0 10 43 4 11 47 4 12 51 4 13 55 4 14 59 4 15 63 0 To display Byte Streaming parameters: switch:admin> portshow fciptunnel ge1 0 -bstr Port: ge1 Tunnel ID 0 Remote IP Addr 192.168.32.2 Local IP Addr 192.168.32.1 Remote WWN Not Configured Local WWN 10:00:00:05:1e:41:2f:2e Compression off Fastwrite on Tape Pipelining off Committed Rate 400000 Kbps (0.400000 Gbps) SACK on Min Retransmit Time 100 Keepalive Timeout 10 Max Retransmissions 8 VC QoS Mapping off DSCP Marking (Control): 0, DSCP Marking (Data): 0 722 Fabric OS Command Reference 53-1001337-01