Canon XF605 Instruction Manual - Page 99

Video Scopes, Displaying a Video Scope, Changing the Waveform Monitor Settings

Page 99 highlights

Video Scopes Video Scopes The camera can display a simplified waveform monitor or a vectorscope to check your recordings. The selected video scope is displayed on the screen and can be output to other monitoring devices as well. 99 Displaying a Video Scope 1 Select > [A Assistance Functions] > [WFM Function] > [Waveform Monitor] or [Vectorscope]. 2 Press the WFM button. • You can also use direct touch control (A 49) to turn the [Waveform Monitor]/[Vectorscope] setting on/off. • Alternatively, you can use one of the > [A Assistance Functions] > [WFM:] settings to turn the video scope on/off separately on the desired video output. • By default, the video scope will appear on the right of the screen. Using the > [A Assistance Functions] > [Waveform Settings] or [Vectorscope Settings] > [Position] settings, you can select where to display it (left or right side). NOTES • The video scopes will also be displayed while adjusting a custom picture file's image settings (A 120). Changing the Waveform Monitor Settings 1 Select > [A Assistance Functions] > [Waveform Settings] > [Type] > Desired option. • If you selected an option other than [Select Line], skip to step 4. 2 Select > [A Assistance Functions] > [Waveform Settings] > [Select Line]. 3 Enter the Y coordinate of the red horizontal line to display using the data entry screen (A 27). • The available range of lines that can be selected depends on the vertical component of the resolution used. For 2160: 0 to 2158 (in 2-line increments) For 1080: 0 to 1079 (in 1-line increments) For 720: 0 to 719 (in 1-line increments) 4 Select > [A Assistance Functions] > [Waveform Settings] > [Vertical Scale for HDR] > Desired option. • Select the Y axis (luminance) scale used when displaying the waveform monitor of an HDR image. 5 Select > [A Assistance Functions] > [Waveform Settings] > [Gain] > [1x] or [2x]. • If you selected [1x], the rest of the procedure is not necessary. 6 Select > [A Assistance Functions] > [Waveform Settings] > [Y Position] > Desired option. • The display range of the waveform monitor's Y axis will be reduced by half. Select the minimum luminance value (in %) shown on the Y axis.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238

99
Video
S
cope
s
Video Scope
s
The camera can display a simplified waveform monitor or a vectorscope to check your recordings. The selected
video scope is displayed on the screen and can be output to other monitoring devices as well.
Di
s
playing a Video Scope
1
S
elect
> [
A
A
ss
i
s
tance Function
s
] >
[WFM Function] > [Waveform Monitor] or
[Vector
s
cope].
2 Pre
ss
the WFM button.
You can also use direct touch control (
A
49) to turn
the [Waveform Monitor]/[Vectorscope] setting on/off.
Alternatively, you can use one of the
>
[
A
Assistance Functions] > [WFM:] settings to turn the
video scope on/off separately on the desired video
output.
By default, the video scope will appear on the right of
the screen. Using the
> [
A
Assistance
Functions] > [Waveform Settings] or [Vectorscope
Settings] > [Position] settings, you can select where to display it (left or right side).
NOTES
NOTES
The video scopes will also be displayed while adjusting a custom picture file's image settings (
A
120).
Changing the Waveform Monitor Setting
s
1
S
elect
> [
A
A
ss
i
s
tance Function
s
] > [Waveform
S
etting
s
] > [Type] > De
s
ired option.
If you selected an option other than [Select Line], skip to step 4.
2
S
elect
> [
A
A
ss
i
s
tance Function
s
] > [Waveform
S
etting
s
] > [
S
elect Line].
3 Enter the Y coordinate of the red horizontal line to di
s
play u
s
ing the data entry
s
creen (
A
27).
The available range of lines that can be selected depends on the vertical component of the resolution used.
For 2160: 0 to 2158 (in 2-line increments)
For 1080: 0 to 1079 (in 1-line increments)
For 720: 0 to 719 (in 1-line increments)
4
S
elect
> [
A
A
ss
i
s
tance Function
s
] > [Waveform
S
etting
s
] > [Vertical
S
cale for HDR] >
De
s
ired option.
Select the Y axis (luminance) scale used when displaying the waveform monitor of an HDR image.
5
S
elect
> [
A
A
ss
i
s
tance Function
s
] > [Waveform
S
etting
s
] > [Gain] > [1x] or [2x].
If you selected [1x], the rest of the procedure is not necessary.
6
S
elect
> [
A
A
ss
i
s
tance Function
s
] > [Waveform
S
etting
s
] > [Y Po
s
ition] > De
s
ired option.
The display range of the waveform monitor’s Y axis will be reduced by half. Select the minimum luminance
value (in %) shown on the Y axis.