Dell PowerEdge T140 EMC PowerEdge Servers Troubleshooting Guide - Page 26
PSA System board - RTC, Dell Technical Support
View all Dell PowerEdge T140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Error number (PSA and ePSA) Error message Description Steps no 2000-0123 memory error & If 3 diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. If failure continues, contact Dell Technical Support PSA 1000-0223 System board - Timer - Interval ePSA 2000-0223 (Not used with UEFI BIOS) timer initial clock output level incorrect An error occurred during the 1 tests that may involve the main system board of the system. If a 2 memory error is detected, try memory modules individually. If 3 no 2000-0123 memory error & If diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. Update to the latest BIOS version. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support PSA 1000-0224 System board - Interval timer ePSA 2000-0224 (Not used with had wrong time period in mode UEFI BIOS) An error occurred during the 1 tests that may involve the main system board of the system. If a 2 memory error is detected, try memory modules individually. If 3 no 2000-0123 memory error & If diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. Update to the latest BIOS version. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support PSA 1000-0231 System board - Failure in Interval An error occurred during the 1 ePSA 2000-0231 (Not used with timer in mode UEFI BIOS) tests that may involve the main system board of the system. If a 2 memory error is detected, try memory modules individually. If 3 no 2000-0123 memory error & If diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. Update to the latest BIOS version. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support PSA 2000-0232 System board - the RTC did not ePSA 2000-0232 (Not used with generate periodic ticks UEFI BIOS) An error occurred during the 1 tests that may involve the main system board of the system. If a 2 memory error is detected, try memory modules individually. If 3 no 2000-0123 memory error & If diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. Update to the latest BIOS version. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support PSA 2000-0233 PSA System board - RTC ePSA 2000-0233 (Not used with UEFI BIOS) 'seconds' count is not updating ePSA RTC - 'seconds' count is not updating An error occurred during the 1 tests that involve the Real Time Clock (RTC) of the main system 2 board in the system. If a memory error is detected, try memory modules individually. If no Update to the latest BIOS version. Repeat the PSA diagnostics 26 Running diagnostics