Con Switch D, Con a static route to 20.1.1.0/24
View all HP 6125G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 208 highlights
[SwitchA] nqa schedule admin test start-time now lifetime forever # Configure track entry 1, and associate it with reaction entry 1 of the NQA test group (with the administrator admin, and the operation tag test). [SwitchA] track 1 nqa entry admin test reaction 1 3. Configure Switch B: # Configure a static route to 30.1.1.0/24, with the address of the next hop as 10.2.1.4. system-view [SwitchB] ip route-static 30.1.1.0 24 10.2.1.4 # Configure a static route to 20.1.1.0/24, with the address of the next hop as 10.1.1.1. [SwitchB] ip route-static 20.1.1.0 24 10.1.1.1 4. Configure Switch C: # Configure a static route to 30.1.1.0/24, with the address of the next hop as 10.4.1.4. system-view [SwitchC] ip route-static 30.1.1.0 24 10.4.1.4 # Configure a static route to 20.1.1.0/24, with the address of the next hop as 10.3.1.1. [SwitchC] ip route-static 20.1.1.0 24 10.3.1.1 5. Configure Switch D: # Configure a static route to 20.1.1.0/24, with the address of the next hop as 10.2.1.2 and the default priority 60. This static route is associated with track entry 1. system-view [SwitchD] ip route-static 20.1.1.0 24 10.2.1.2 track 1 # Configure a static route to 20.1.1.0/24, with the address of the next hop as 10.4.1.3 and the priority 80. [SwitchD] ip route-static 20.1.1.0 24 10.4.1.3 preference 80 # Configure a static route to 10.1.1.1, with the address of the next hop as 10.2.1.2. [SwitchD] ip route-static 10.1.1.1 24 10.2.1.2 # Create an NQA test group with the administrator admin and the operation tag test. [SwitchD] nqa entry admin test # Configure the test type as ICMP-echo. [SwitchD-nqa-admin-test] type icmp-echo # Configure the destination address of the test as 10.1.1.1 and the next hop address as 10.2.1.2 to check the connectivity of the path from Switch D to Switch B and then to Switch A through NQA. [SwitchD-nqa-admin-test-icmp-echo] destination ip 10.1.1.1 [SwitchD-nqa-admin-test-icmp-echo] next-hop 10.2.1.2 # Configure the test frequency as 100 ms. [SwitchD-nqa-admin-test-icmp-echo] frequency 100 # Configure reaction entry 1, specifying that five consecutive probe failures trigger the track module. [SwitchD-nqa-admin-test-icmp-echo] reaction 1 checked-element probe-fail threshold-type consecutive 5 action-type trigger-only [SwitchD-nqa-admin-test-icmp-echo] quit # Start the NQA test. [SwitchD] nqa schedule admin test start-time now lifetime forever # Configure track entry 1, and associate it with reaction entry 1 of the NQA test group (with the administrator admin, and the operation tag test). 201