HP Z620 HP Remote Graphics Software 5.4.7 - Page 195

Receiver experience properties, Rgreceiver.IsDisconnectWarningEnabled=bool 0

Page 195 highlights

When the Rgreceiver.IsAutoMenubarEnabled.IsMutable property is set to 0, the user cannot turn Auto show toolbar feature on in the Receivers Advanced->General tab. Rgreceiver.IsDisconnectWarningEnabled=bool (0) This property was added with RGS 5.4.5 and allows the user to enable a warning dialog when closing the RGS window while RGS is still connected. This warning dialog will warn the user that disconnecting from RGS while they are still logged in will not log the user out of the remote system. Receiver experience properties Rgreceiver.Experience.IsMutable=bool (1) When set to 1, the default, the user can turn this feature on and off in the Receivers Advanced>General tab, Experience section. Setting to 0 disables the user's ability to turn the feature on and off. Rgreceiver.Experience.Mode=FixedImageQuality | AdjustImageQuality This property allows the user to set the startup behavior for the interactive experience controls. FixedImageQuality is the default. AdjustImageQuality will cause RGS to use the settings for Minimum image quality and Minimum update rate and adjust the image if needed. Rgreceiver.Experience.MinImageQuality=int (20) Controls the startup value for image quality if AdjustImageQuality is enabled. The minimum image quality specifies the lowest quality level that will be used during the automatic adjustment. The minimum image quality is absolute - the system will not lower quality below the specified value. Values are from 0 to 100 with a default of 20. Rgreceiver.Experience.MinUpdateRate=int (30) Controls the startup value for minimum update rate if AdjustImageQuality is enabled. The minimum update rate controls how aggressively the image quality is reduced. Specifying a minimum update rate of 30 will drive the most aggressive quality reduction. The minimum update rate is a target. The available bandwidth may be too low to maintain the target rate. Values are from 0 to 30 with a default of 30. Receiver browser properties Rgreceiver.Browser.IsMutable=bool (1) This property only applies to the Linux RGS Receiver. If set to 1, the name of the browser used to display online help can be changed by the user in the Receiver Control panel. If set to 0, the name of the browser cannot be changed by the user. Rgreceiver.Browser.Name=string (mozilla) Rgreceiver.Browser.Name.IsMutable=bool (1) This property only applies to the Linux RGS Receiver, and can be used to set the name of the browser to display online help. For example, setting Rgreceiver.Browser.Name=mozilla will start the Mozilla browser when the Help button is clicked in the Receiver Control Panel. For the Windows Receiver, the Help system is based on a CHM file. RGS Receiver properties 179

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247

When the Rgreceiver.IsAutoMenubarEnabled.IsMutable property is set to 0, the user cannot turn Auto
show toolbar feature on in the Receivers
Advanced->General
tab.
Rgreceiver.IsDisconnectWarningEnabled=bool (0)
This property was added with RGS 5.4.5 and allows the user to enable a warning dialog when closing
the RGS window while RGS is still connected. This warning dialog will warn the user that disconnecting
from RGS while they are still logged in will not log the user out of the remote system.
Receiver experience properties
Rgreceiver.Experience.IsMutable
=bool
1)
When set to 1, the default, the user can turn this feature on and off in the Receivers
Advanced-
>General
tab,
Experience
section. Setting to 0 disables the user's ability to turn the feature on and
off.
Rgreceiver.Experience.Mode
=FixedImageQuality | AdjustImageQuality
This property allows the user to set the startup behavior for the interactive experience controls.
FixedImageQuality is the default. AdjustImageQuality will cause RGS to use the settings for Minimum
image quality and Minimum update rate and adjust the image if needed.
Rgreceiver.Experience.MinImageQuality
=int (20)
Controls the startup value for image quality if AdjustImageQuality is enabled. The minimum image
quality specifies the lowest quality level that will be used during the automatic adjustment. The minimum
image quality is absolute - the system will not lower quality below the specified value. Values are from
0 to 100 with a default of 20.
Rgreceiver.Experience.MinUpdateRate
=int (30)
Controls the startup value for minimum update rate if AdjustImageQuality is enabled. The minimum
update rate controls how aggressively the image quality is reduced. Specifying a minimum update rate
of 30 will drive the most aggressive quality reduction. The minimum update rate is a target. The
available bandwidth may be too low to maintain the target rate. Values are from 0 to 30 with a default
of 30.
Receiver browser properties
Rgreceiver.Browser.IsMutable
=bool
1
This property only applies to the Linux RGS Receiver. If set to 1, the name of the browser used to
display online help can be changed by the user in the Receiver Control panel. If set to 0, the name of
the browser cannot be changed by the user.
Rgreceiver.Browser.Name=string
mozilla
Rgreceiver.Browser.Name.IsMutable=bool
1
This property only applies to the Linux RGS Receiver, and can be used to set the name of the browser to
display online help. For example, setting Rgreceiver.Browser.Name=mozilla will start the Mozilla
browser when the
Help
button is clicked in the Receiver Control Panel.
For the Windows Receiver, the Help system is based on a CHM file.
RGS Receiver properties
179