Fixed Disk with SCSI ID NN, Adapter in Slot N
UPC - 087944534341
View all IBM 6000R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 174 highlights
Error Code/Symptom 020-XXX-003 (Failed Hot-Swap Slot 3 PCI Latch test) 020-XXX-004 (Failed Hot-Swap Slot 4 PCI Latch test) 020-XXX-005 (Failed Hot-Swap Slot 5 PCI Latch test) 020-XXX-006 (Failed Hot-Swap Slot 6 PCI Latch test) 030-XXX-000 (Failed Internal SCSI interface test) 030-XXX-00N (Failed SCSI test on PCI slot N. Check system error log before replacing a FRU.) 035-XXX-099 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 035-XXX-SNN (Check System Error Log before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) FRU/Action 1. PCI Hot-Swap Latch Assembly 2. System Board 1. PCI Hot-Swap Latch Assembly 2. System Board 1. PCI Hot-Swap Latch Assembly 2. System Board 1. PCI Hot-Swap Latch Assembly 2. System Board 1. System Board 1. Adapter in Slot N 1. No adapters were found. 2. If adapter is installed re-check connection. 1. Adapter 2. SCSI Backplane 3. Cable 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. 162 Netfinity 6000R Type 8682 Models 1RY, 2RY