Error Code/Symptom 180-XXX-004 (Failed Processor LED test) 180-XXX-005 (Failed SCSI Backplane LED test) 180-XXX-006 (Memory Board LED test) 201-XXX-0NN (Failed Memory test, see "Memory Settings" on page 47.) NN = DIMM location. 201-XXX-999 (Multiple DIMM failure, see error text.) 202-XXX-001 (Failed System Cache test) 202-XXX-002 (Failed System Cache test) 202-XXX-003 (Failed System Cache test) 202-XXX-004 (Failed System Cache test) 206-XXX-000 (Failed Diskette Drive test) 215-XXX-000 (Failed IDE CDROM test) 217-XXX-000 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. FRU/Action 1. System Board 1. SCSI Backplane 2. SCSI Backplane Cable 3. System Board 1. Memory Board 2. System Board 1. DIMM Location J1-J16 2. Memory card 1. See error text for failing DIMMs 2. Memory card 1. Microprocessor CPU 1 1. Microprocessor CPU 2 1. Microprocessor CPU 3 1. Microprocessor CPU 4 1. Cable 2. Diskette Drive 3. System Board 1. CD-ROM Drive Cables 2. CD-ROM Drive 3. System Board 1. Fixed Disk 1 164 Netfinity 6000R Type 8682 Models 1RY, 2RY