IBM 6000R Hardware Maintenance Manual - Page 73
Hard disk drive fault, Fan failure
UPC - 087944534341
View all IBM 6000R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
CPU Memory PCI Bus A B C D Power Supply 1 2 3 4 Fan DASD NMI SP Bus Event Log Non Red Over Spec Temp 1 System board connector 2 Diskette drive connector The meanings of these LEDs are as follows: CPU Microprocessor fault Memory Memory fault PCI Bus A (PCIA) PCI bus A fault PCI Bus B (PCIB) PCI bus B fault PCI Bus C (PCIC) PCI bus C fault PCI Bus D (PCID) Not implemented at this time. Power supply 1 Power supply number 1 failure Power supply 2 Power supply number 2 failure Power supply 3 Power supply number 3 failure FAN Fan failure DASD Hard disk drive fault NMI Nonmaskable interrupt SP Bus Service processor failure Event Log Not implemented at this time. NON RED Nonredundant power mode OVER SPEC Over specification TEMP System temperature failure Installing options 61