Run Configuration/Setup, Code/Symptom

Page 185 highlights

Error Code/Symptom 184 (Power-on password corrupted) 185 (Drive startup sequence information corrupted) 186 (Security hardware control logic failed) 187 (VPD serial number not set.) 188 (Bad EEPROM CRC #2) 189 (Three attempts were made to access the server with invalid passwords) 201 (Memory test error, see "Memory Settings" on page 47.) If the server does not have the latest level of BIOS installed, update the BIOS to the latest level and run the diagnostic program again. 229 (Cache error) 289 (DIMM has been disabled by user or system, see "Memory Settings" on page 47.) 301 (Keyboard or keyboard controller error) FRU/Action 1. Run Configuration/Setup 2. System Board 1. Run Configuration/Setup 2. System Board 1. Run Configuration/Setup 2. System Board 1. Set serial number in Setup 2. System Board 1. Run Configuration/Setup 2. System Board 1. Run Configuration/Setup, enter the administrator password 2. System Board. 1. Run memory diagnostics. 2. DIMM 3. Memory card 4. System Board 1. Processor 2. Optional Processor (if installed) 1. Run Configuration/Setup 2. Disabled DIMM 1. Keyboard 2. System Board Symptom-to-FRU index 173

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

Symptom-to-FRU index
173
184
(Power-on
password
corrupted)
1.
Run Configuration/Setup
2.
System Board
185
(Drive startup
sequence
information
corrupted)
1.
Run Configuration/Setup
2.
System Board
186
(Security hardware
control logic failed)
1.
Run Configuration/Setup
2.
System Board
187
(VPD serial number
not set.)
1.
Set serial number in Setup
2.
System Board
188
(Bad EEPROM
CRC #2)
1.
Run Configuration/Setup
2.
System Board
189
(Three attempts
were made to
access the server
with invalid
passwords)
1.
Run Configuration/Setup,
enter the administrator
password
2.
System Board.
201
(Memory test error,
see "Memory
Settings" on page
47.)
If the server
does not have the
latest level of BIOS
installed, update
the BIOS to the
latest level and run
the diagnostic
program again.
1.
Run memory diagnostics.
2.
DIMM
3.
Memory card
4.
System Board
229
(Cache error)
1.
Processor
2.
Optional Processor
(if
installed)
289
(DIMM has been
disabled by user or
system, see
"Memory Settings"
on page 47.)
1.
Run Configuration/Setup
2.
Disabled DIMM
301
(Keyboard or
keyboard controller
error)
1.
Keyboard
2.
System Board
Error
Code/Symptom
FRU/Action