IBM 6000R Hardware Maintenance Manual - Page 48

The Protocol Manager Input Output, Control IOCTL failed.

Page 48 highlights

Table 4. NDIS 2.01 (OS/2) driver messages for the Ethernet controller PCNTND-10 The Protocol Manager Input Output Control (IOCTL) failed. PCNTND-11 Explanation: The NDIS stack is not configured correctly in the PROTOCOL.INI file. Action: Check and correct the configuration. Protocol Manager registration failed. PCNTND-15 Explanation: The NDIS stack is not configured correctly. Action: Check and correct the configuration. Device not found. PCNTND-16 Explanation: The driver cannot find an Ethernet controller in the server. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic programs" on page 17 to run the diagnostic programs. PCI scan specified, device not found. PCNTND-21 Explanation: The driver cannot locate the Ethernet controller on the PCI bus. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic programs" on page 17 to run the diagnostic programs. The adapter failed the checksum test. PCNTND-23 Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic programs" on page 17 to run the diagnostic programs. WARNING: PCNET IRQ found = xx Explanation: The interrupt request (IRQ) setting (xx) in the PROTOCOL.INI file does not match the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI file or change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the PCI Slot/Device Information selection of the Advanced Setup menu in the Configuration/Setup Utility program. 36 Netfinity 6000R Type 8682 Models 1RY, 2RY

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

36
Netfinity 6000R Type 8682 Models 1RY, 2RY
PCNTND-10
The Protocol Manager Input Output
Control (IOCTL) failed.
Explanation:
The NDIS stack is not
configured correctly in the
PROTOCOL.INI file.
Action:
Check and correct the
configuration.
PCNTND-11
Protocol Manager registration failed.
Explanation:
The NDIS stack is not
configured correctly.
Action:
Check and correct the
configuration.
PCNTND-15
Device not found.
Explanation:
The driver cannot find an
Ethernet controller in the server.
Action:
Verify that the Ethernet controller
is enabled.
If the Ethernet controller is
enabled, go to “Starting the diagnostic
programs” on page 17 to run the
diagnostic programs.
PCNTND-16
PCI scan specified, device not found.
Explanation:
The driver cannot locate
the Ethernet controller on the PCI bus.
Action:
Verify that the Ethernet controller
is enabled.
If the Ethernet controller is
enabled, go to “Starting the diagnostic
programs” on page 17 to run the
diagnostic programs.
PCNTND-21
The adapter failed the checksum test.
Explanation:
The driver cannot find an
Ethernet controller.
Action:
Verify that the Ethernet controller
is enabled.
If the Ethernet controller is
enabled, go to “Starting the diagnostic
programs” on page 17 to run the
diagnostic programs.
PCNTND-23
WARNING:
PCNET IRQ found =
xx
Explanation:
The interrupt request (IRQ)
setting (
xx
) in the PROTOCOL.INI file
does not match the hardware IRQ setting.
Action:
Remove the IRQ setting from the
PROTOCOL.INI file or change the IRQ
setting in the PROTOCOL.INI file to
match the IRQ setting shown in the
PCI
Slot/Device Information
selection of the
Advanced Setup menu in the
Configuration/Setup Utility program.
Table 4. NDIS 2.01 (OS/2) driver messages for the Ethernet
controller