IBM 6000R Hardware Maintenance Manual - Page 46

Table 3. Novell NetWare or IntraNetWare ODI driver, messages for the Ethernet controller

Page 46 highlights

Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller PCNTNWNW-126 The group bit in the node address override was cleared. PCNTNWNW-127 Explanation: The IEEE address has a group bit that indicates that an address belongs to a group of stations. This bit is used only as a destination address; it cannot be used as a source address. You tried to enter a source address with this bit set. The driver cleared the group bit of the source address. Action: None necessary, message is for information only. The local bit in the node address override was set. PCNTNWNW-164 PCNTNWNW-165 Explanation: The local bit in the IEEE address format indicates that the addresses are being managed locally. If you use the node address override capabilities of this driver to enter a new address, the local bit must be set. You entered an address without the local bit set. The driver has set the local bit. Action: None necessary, message is for information only. The device was not found. Explanation: The driver cannot find an Ethernet controller in the server. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic programs" on page 17 to run the diagnostic programs. The device was not found at IOADDRESS. PCNTNWNW-167 Explanation: The Ethernet controller cannot be found at the I/O address specified. Action: The Ethernet controller does not require a parameter for the I/O address. Remove the I/O address parameter. PCI scan specified, device not found. Explanation: The driver cannot locate the Ethernet controller on the PCI bus. Action: Verify that the Ethernet controller is enabled. If the problem persists, go to "Starting the diagnostic programs" on page 17 to run the diagnostic programs. 34 Netfinity 6000R Type 8682 Models 1RY, 2RY

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

34
Netfinity 6000R Type 8682 Models 1RY, 2RY
PCNTNW-
NW-126
The group bit in the node address
override was cleared.
Explanation:
The IEEE address has a
group bit that indicates that an address
belongs to a group of stations.
This bit is
used only as a destination address; it
cannot be used as a source address.
You
tried to enter a source address with this bit
set.
The driver cleared the group bit of the
source address.
Action:
None necessary, message is for
information only.
PCNTNW-
NW-127
The local bit in the node address
override was set.
Explanation:
The local bit in the IEEE
address format indicates that the
addresses are being managed locally.
If
you use the node address override
capabilities of this driver to enter a new
address, the local bit must be set.
You
entered an address without the local bit
set.
The driver has set the local bit.
Action:
None necessary, message is for
information only.
PCNTNW-
NW-164
The device was not found.
Explanation:
The driver cannot find an
Ethernet controller in the server.
Action:
Verify that the Ethernet controller
is enabled.
If the Ethernet controller is
enabled, go to “Starting the diagnostic
programs” on page 17 to run the
diagnostic programs.
PCNTNW-
NW-165
The device was not found at
IOADDRESS.
Explanation:
The Ethernet controller
cannot be found at the I/O address
specified.
Action:
The Ethernet controller does not
require a parameter for the I/O address.
Remove the I/O address parameter.
PCNTNW-
NW-167
PCI scan specified, device not found.
Explanation:
The driver cannot locate
the Ethernet controller on the PCI bus.
Action:
Verify that the Ethernet controller
is enabled.
If the problem persists, go to
“Starting the diagnostic programs” on
page 17 to run the diagnostic programs.
Table 3. Novell NetWare or IntraNetWare ODI driver
messages for the Ethernet controller