IBM 6000R Hardware Maintenance Manual - Page 188

System Board, Verify a bootable operating, system is installed., Video Adapter if installed, Error

Page 188 highlights

Error Code/Symptom 1601 (The system is able to communicate to the Service Processor, but the Service Processor failed to respond at the start of POST.) Do the following before replacing a FRU: 1. Remove the ac power to the system, wait 20 seconds; then, re-connect the ac power. Wait 30 seconds; then, power-on the system. 2. Flash update the Service Processor. 1800 (No more hardware interrupt available for PCI adapter) 1962 (Drive does not contain a valid boot sector) 2400 (Video controller test failure) 2462 (Video memory configuration error) FRU/Action 1. System Board 2. Service Processor Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Verify a bootable operating system is installed. 2. If RAID system, refer to the Hardware Maintenance Manual for the specific RAID adapter. 3. Run Diagnostics 4. Hard Disk Drive 5. Cable 6. SCSI Backplane 7. System Board 1. Video Adapter (if installed) 2. System Board 1. Video Adapter (if installed) 2. System Board 176 Netfinity 6000R Type 8682 Models 1RY, 2RY

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

176
Netfinity 6000R Type 8682 Models 1RY, 2RY
1601
(The system is able
to communicate to
the Service
Processor, but the
Service Processor
failed to respond at
the start of POST.)
Do the following
before replacing a
FRU:
1.
Remove the
ac power to
the system,
wait 20
seconds; then,
re-connect the
ac power.
Wait 30
seconds; then,
power-on the
system.
2.
Flash update
the Service
Processor.
1.
System Board
2.
Service Processor Board
1800
(No more hardware
interrupt available
for PCI adapter)
1.
Run Configuration/Setup
2.
Failing Adapter
3.
System Board
1962
(Drive does not
contain a valid boot
sector)
1.
Verify a bootable operating
system is installed.
2.
If RAID system, refer to the
Hardware Maintenance
Manual for the specific RAID
adapter.
3.
Run Diagnostics
4.
Hard Disk Drive
5.
Cable
6.
SCSI Backplane
7.
System Board
2400
(Video controller
test failure)
1.
Video Adapter (if installed)
2.
System Board
2462
(Video memory
configuration error)
1.
Video Adapter (if installed)
2.
System Board
Error
Code/Symptom
FRU/Action