IBM 6000R Hardware Maintenance Manual - Page 84

See System board, Plastic dividers

Page 84 highlights

hard disk drives. You can also cable a ServeRAID adapter to external hard disk drives. Notes: 1. The illustrations in this document might differ slightly from your hardware. 2. Refer to the documentation that comes with your adapter for any cabling instructions. 3. Cable identifiers are printed on the cables that come with the server and options. Use these identifiers to connect the cables to the correct connectors. For example, the hard disk drive cables are labeled HDD. To cable the ServeRAID adapter: 1. Turn off the server. 2. Remove all adapters from the Active PCI adapter slots. 3. Remove the plastic dividers between the PCI adapter slots. 4. Press the fan assembly release latches on both sides of the fan assembly; then, remove the fan assembly from the server. 1 Plastic dividers 2 Fan assembly release latch 3 ServeRAID adapter 5. Disconnect the internal SCSI cable from the SCSI connector (J38) on the system board. (See "System board cable connectors" on page 55). 6. Carefully thread the disconnected end of the internal SCSI cable out of the chassis, pulling the cable out of the opening in the chassis. 7. Reinstall the fan assembly in the server. 72 Netfinity 6000R Type 8682 Models 1RY, 2RY

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

72
Netfinity 6000R Type 8682 Models 1RY, 2RY
hard disk drives.
You can also cable a ServeRAID adapter
to external hard disk drives.
Notes:
1.
The illustrations in this document might differ slightly
from your hardware.
2.
Refer to the documentation that comes with your
adapter for any cabling instructions.
3.
Cable identifiers are printed on the cables that come
with the server and options.
Use these identifiers to
connect the cables to the correct connectors.
For
example, the hard disk drive cables are labeled HDD.
To cable the ServeRAID adapter:
1.
Turn off the server.
2.
Remove all adapters from the Active PCI adapter slots.
3.
Remove the plastic dividers between the PCI adapter
slots.
4.
Press the fan assembly release latches on both sides
of the fan assembly; then, remove the fan assembly
from the server.
±
1
²
Plastic dividers
±
2
²
Fan assembly release latch
±
3
²
ServeRAID adapter
5.
Disconnect the internal SCSI cable from the SCSI con-
nector (J38) on the system board.
(See “System board
cable connectors” on page 55).
6.
Carefully thread the disconnected end of the internal
SCSI cable out of the chassis, pulling the cable out of
the opening in the chassis.
7.
Reinstall the fan assembly in the server.