IBM 6000R Hardware Maintenance Manual - Page 49

NDIS 4.0 (Windows NT) driver messages, The specified I/O address

Page 49 highlights

Table 4. NDIS 2.01 (OS/2) driver messages for the Ethernet controller PCNTND-24 WARNING: PCNET IRQ does not match PROTOCOL.INI. PCNTND-25 Explanation: The interrupt request (IRQ) setting in the PROTOCOL.INI file does not match the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI file or change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the PCI Slot/Device Information selection of the Advanced Setup menu in the Configuration/Setup Utility program. PCI scan specified, PCI bus not found! PCNTND-29 Explanation: The driver cannot locate the PCI bus. Action: Run the diagnostic programs. WARNING: DMA number is not necessary for PCI device. PCNTND-33 Explanation: The Ethernet controller does not require a DMA setting. Action: Remove the DMA setting in the PROTOCOL.INI file. PCNET device with specified IOBASE is already in use. Explanation: The specified I/O address number is already in use by another Ethernet controller or device. Action: Remove the I/O address setting in the PROTOCOL.INI file. NDIS 4.0 (Windows NT) driver messages This section contains the error messages for the NDIS 4.0 drivers. The explanation and recommended action are included with each message. Table 5. NDIS (Windows NT) driver messages for the Ethernet controller PermaNet™ No Secondary Adapter Found. Server: Grouping Mode is disabled. Explanation: The failover option requires an adapter that is compatible with the device driver of the Ethernet controller on the system board. No such adapter was found. Action: Make sure the correct adapter is installed. Diagnostics 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

Diagnostics
37
NDIS 4.0 (Windows NT) driver messages
This section contains the error messages for the NDIS 4.0
drivers.
The explanation and recommended action are
included with each message.
PCNTND-24
WARNING:
PCNET IRQ does not
match PROTOCOL.INI.
Explanation:
The interrupt request (IRQ)
setting in the PROTOCOL.INI file does
not match the hardware IRQ setting.
Action:
Remove the IRQ setting from the
PROTOCOL.INI file or change the IRQ
setting in the PROTOCOL.INI file to
match the IRQ setting shown in the
PCI
Slot/Device Information
selection of the
Advanced Setup menu in the
Configuration/Setup Utility program.
PCNTND-25
PCI scan specified, PCI bus not found!
Explanation:
The driver cannot locate
the PCI bus.
Action:
Run the diagnostic programs.
PCNTND-29
WARNING:
DMA number is not
necessary for PCI device.
Explanation:
The Ethernet controller
does not require a DMA setting.
Action:
Remove the DMA setting in the
PROTOCOL.INI file.
PCNTND-33
PCNET device with specified IOBASE
is already in use.
Explanation:
The specified I/O address
number is already in use by another
Ethernet controller or device.
Action:
Remove the I/O address setting
in the PROTOCOL.INI file.
Table 5. NDIS (Windows NT) driver messages for the
Ethernet controller
PermaNet
Server:
No Secondary Adapter Found.
Grouping Mode is disabled.
Explanation:
The failover option requires
an adapter that is compatible with the
device driver of the Ethernet controller on
the system board.
No such adapter was
found.
Action:
Make sure the correct adapter is
installed.
Table 4. NDIS 2.01 (OS/2) driver messages for the Ethernet
controller