IBM 6000R Hardware Maintenance Manual - Page 175
Run Diagnostic LED test for, ServeRAID Adapter in slot S
UPC - 087944534341
View all IBM 6000R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 175 highlights
Error Code/Symptom 035-253-S99 (RAID adapter initialization failure) 075-XXX-000 (Failed Power Supply test) 089-XXX-001 (Failed Microprocessor test) 089-XXX-002 (Failed Optional Microprocessor test) 089-XXX-003 (Failed Optional Microprocessor test) 089-XXX-004 (Failed Optional Microprocessor test) 165-XXX-000 (Failed Service Processor test) 180-XXX-000 (Diagnostics LED failure) 180-XXX-001 (Failed information LED panel test) 180-XXX-002 (Failed Diagnostics LED Panel test) 180-XXX-003 (Failed System Board LED test) FRU/Action 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. SCSI Backplane 4. Adapter 1. Power Supply 1. Microprocessor 1. Optional Microprocessor 2 1. Optional Microprocessor 3 1. Optional Microprocessor 4 1. Service Processor Board. 2. System Board. Before replacing the System Board, ensure that System Board jumper J5 is not installed (the default) when the error occurs. 1. Run Diagnostic LED test for the failing LED. 1. Information LED Panel 2. Diagnostic LED Panel 3. System Board 1. Diagnostics LED Panel 2. System Board 1. System Board Symptom-to-FRU index 163