HP rp3440 User Service Guide, Sixth Edition - HP 9000 rp3410/rp3440 - Page 205
C Physical and Environmental Specifications
View all HP rp3440 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 205 highlights
C Physical and Environmental Specifications Table C-1 provides temperature and airflow information for minimum, typical, and maximum configurations for the HP 9000 rp3410 and rp3440 servers. It also lists the server and rack weights and dimensions. Table C-1 Physical and Environmental Specifications Condition Typical Heat Release 100-250 VAC Weight Airflow, Nominal Airflow, at Maximum Ambient degrees C1 Server Alone Rack Overall Server (W x D x H) Pede- Rack stal Pede-stal Min. 341 Watts Config. Max. 536 Watts Config. Typical 426 Watts Config. 57.8 CFM 98.3 m3/hr 68.2 CFM 115.94 m3/hr 38.6 lbs 49.0 lbs 56.3 lbs W: 19.0 in W: 11.6 in (17.5 kg) (22.2 kg) (25.5 (48.3 cm) (29.5 cm) kg) D: 26.8 in D: 26.6 in (67.9 cm) (67.5 cm) H: 3.4 in H: 19.5 in (8.6 cm) (49.4 cm) ASHRAE Airflow cooling scheme (front to rear) Min./ One dual-core CPU, one power supply, 2 GB DIMM, Class 1 Config. zero DVD, three HDDs. Max. Two dual-core CPUs, one power supply, 32 GB Config. DIMM, one DVD, three HDDs, one graphics card, one SCSI card. Typical One dual-core CPU, one power supply, 6 GB DIMM, Config. one DVD, three HDDs, one graphics card, one SCSI card. 1 Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters. 205