Netgear GSM7328SO Command Line Interface (CLI) User Manual - Page 620
show sflow agent, no sflow poller
UPC - 606449080162
View all Netgear GSM7328SO manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 620 highlights
ProSafe Managed Switch Field Receiver Index Poll Interval Description Enter the sFlow Receiver associated with the sampler/poller. A value of zero (0) means that no receiver is configured. The range is 1-8. The default is 0. Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter sampling. When set to zero (0), all the poller parameters are set to their corresponding default value. The range is 0-86400. The default is 0. A value of N means once in N seconds a counter sample is generated. no sflow poller Use this command to reset the sFlow poller instance to the default settings. Format Mode no sflow poller { | interval } Interface Config show sflow agent The sFlow agent collects time-based sampling of network interface statistics and flow-based samples. These are sent to the configured sFlow receivers. Use this command to display the sFlow agent information. Format Mode show sflow agent Privileged EXEC Field sFlow Version IP Address Description Uniquely identifies the version and implementation of this MIB. The version string must have the following structure: MIB Version; Organization; Software Revision where: • MIB Version: '1.3', the version of this MIB. • Organization: Netgear. • Revision: 1.0 The IP address associated with this agent. Example: The following shows example CLI display output for the command. (switch) #show sflow agent sFlow Version 1.3;Netgear;1.0 IP Address 10.131.12.66 Utility Commands 620