HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 124
Table 5 Con command fabric parameters fields, Fabric OS commands, number, varies
![]() |
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 124 highlights
Table 5 lists the fabric parameters fields and their settings. Table 5 Configure command fabric parameters fields Field Type Default Range Domain number 1 varies R_A_TOV number 10000 E_D_TOV * 2 to 120000 E_D_TOV number 2000 1000 to R_A_TOV / 2 WAN_TOV number 0 0 to R_A_TOV / 4 MAX_HOPS number 7 7 to 19 Data Field Size number 2112 256 to 2112 Sequence Level Switching boolean 0 0 or 1 Disable Device Probing boolean 0 0 or 1 Suppress Class F Traffic boolean 0 0 or 1 Switch PID Format number 1 1 to 2 Per-frame Route Priority boolean 0 0 or 1 Long Distance Fabric boolean 0 0 or 1 BB Credit number 16 1 to 27 Insistent Domain ID Mode boolean 0 0 or 1 Descriptions of the switch fabric setting fields are as follows: Domain R_A_TOV The domain number uniquely identifies the switch in a fabric. This value is automatically assigned by the fabric. The range of valid values varies depending on the switch model and other system parameter settings. The resource allocation time out value (R_A_TOV) is displayed in milliseconds. This variable works with the variable E_D_TOV to determine switch actions when presented with an error condition. E_D_TOV WAN_TOV Allocated circuit resources with detected errors are not released until the time value has expired. If the condition is resolved prior to the time out, the internal time-out clock resets and waits for the next error condition. Error detect time out value (E_D_TOV) is displayed in milliseconds. This timer is used to flag a potential error condition when an expected response is not received (an acknowledgment or reply in response to packet receipt, for example) within the set time limit. If the time for an expected response exceeds the set value, then an error condition occurs. Wide area network time out value (WAN_TOV) displays in milliseconds. This timer is the maximum frame time out value for a WAN, if any, interconnecting the Fibre Channel islands. 124 Fabric OS commands
![](/manual_guide/products/hewlettpackard-storageworks-264-hp-storageworks-fabric-os-5x-command-reference-guide-aarvhvbte-2005-b63918e/124.png)