HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.x Command Reference Guide (AA - Page 69
burninLevel
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
burninLevel Sets the diagnostics burn-in level. Synopsis burninlevel [ level | -show ] Availability admin Description Use this command to select or display the burn-in level. When the burn-in level is set to a value other than 0, the diagnostic daemon program performs burn-in testing in place of the power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as soon as this command is executed so that it does not require a reboot to take effect. When a burn-in level other than 0 is selected, actual behavior is determined by the configuration of the diagnostics daemon and the burn-in scripts run. A useful application of this command is to store errors on the local persistent error storage on which the error occurs. This happens when the burn-in level is other than 0. This preserves the errors prior to returning a board for service. For multibladed products, this is the independent blade, and for fixed-port-count products, this is the chassis-persistent storage. The error logs are viewed using the burninErrShow command. Operands The following are optional: level -show The burn-in level is set to this value. If specified, or if level is not specified, the current burn-in level setting appears. Examples To set the diagnostic burn-in level: switch:admin> burninlevel -show Burnin level is 0. See also burninErrShow diagDisablePost diagEnablePost diagSetBurnin Fabric OS 5.x command reference guide 69