CPU Interface Filtering Rule Display window Ethernet, Ethernet Type, Time Range
UPC - 790069291982
View all D-Link DGS-3426P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 277 highlights
xStack® DGS-3400 Series Layer 2 Gigabit Ethernet Managed Switch MAC Ethernet Type Specifies that the access profile will apply only to packets with this hexadecimal 802.1Q Ethernet type value (hex 0x0-0xffff) in the packet header. The Ethernet type value may be set in the form: hex 0x0-0xffff, which means the user may choose a combination of letters and numbers ranging from a-f and from 0-9. Port Enter the port or range of ports. Time Range Click the check box and enter the name of the Time Range settings that has been previously configured in the Time Range Settings window. This will set specific times when this access rule will be implemented on the Switch. Click Apply to implement the changes. To view the settings of a previously correctly configured rule, click View in the CPU Interface Filtering Rule Table window to view the following window: Figure 5 - 39 CPU Interface Filtering Rule Display window (Ethernet) The following window is the CPU Interface Filtering Rule Table for IP. Figure 5 - 40 CPU Interface Filtering Rule Table window (IP) To create a new rule set for an access profile click the Add Rule button. A new window is displayed. To remove a previously created rule, click the corresponding button. The following window is used for the IP Rule configuration. 268