Panasonic WJ-ND400K Operating Instructions - Page 169
Site alarm, Site alarm settings
View all Panasonic WJ-ND400K manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
Event Site alarm Use the following procedure to configure settings that control terminal alarm action when a Panasonic alarm protocol alarm (site alarm) is sent from a camera. 1 Click the [Event] button on the setup menu. 2 On the sub-menu that appears, click [Site alarm]. This will display the site alarm setting window. 3 Configure the settings for each item. Refer to "Site alarm settings" table for details about the settings. • To configure the settings of a camera that is not shown on the display, click the applicable camera number range above the [Set] button to change the contents of the display. • Clicking a camera number range saves the currently displayed camera settings. 4 Click the [Set] button. Site alarm settings Item Site alarm Port number (from camera to ND400) Site alarm setup Rec. cam. Preset position Output terminal ♦Initial default Settings Off♦ / On Port number input (1818♦) Cam.1 to Cam.64 / -Signal input (Blank♦) Off / On♦ Description Specifies whether to validate the site alarm. Specifies the port number that receives the site alarm. Specifies the channel of the recording camera. Specifies the preset position (1 to 256) during alarm input. • When this setting is blank, the camera does not move to a preset position. Specifies whether an alarm signal should be output when an event occurs. 40