Dell PowerEdge FX2 Dell PowerEdge FN I/O Aggregator Command Line Reference Gui - Page 290
show fc sw, Field, Description, FCF Priority, Config-State, Oper-State, Members, Example, Related
View all Dell PowerEdge FX2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 290 highlights
Example Related Commands Field FCF Priority Config-State Oper-State Members Description The priority used by a server to select an upstream FCoE forwarder. Indicates whether the configured FCoE and FC parameters in the FCoE map are valid: Active (all mandatory FCoE and FC parameters are correctly configured) or Incomplete (either the FC-MAP value, fabric ID, or VLAN ID are not correctly configured). Operational status of link to the fabric: Up (link is up and transmitting FC traffic), Down (link is down and not transmitting FC traffic), Link-wait (link is up and waiting for FLOGI to complete on peer FC port), or Removed (port has been shut down). FN2210S Aggregator with the FC Flex IO module Ethernet and FC ports that are members of the dedicated FCoE VLAN that carries storage traffic to the specified fabric. Dell#show fcoe-map brief Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config- State Oper-State test 16 16 0efc02 128 ACTIVE UP cnatest 1003 1003 0efc03 128 ACTIVE UP sitest 1004 1004 0efc04 128 ACTIVE DOWN Dell#show fcoe-map si Fabric Name Fabric Id Vlan Id Vlan priority FC-MAP FKA-ADV-Period Fcf Priority Config-State Oper-State Members si 1004 1004 3 0efc04 8 128 ACTIVE DOWN fcoe-map - creates an FCoE map which contains the parameters used in the communication between servers and a SAN fabric. show fc sw Display the switch configuration for Fibre Channel capability. Syntax show fc sw 290