Dell PowerEdge FX2 Dell PowerEdge FN I/O Aggregator Command Line Reference Gui - Page 302
fcoe-map, Introduced on the M I/O Aggregator with the PMUX module.
View all Dell PowerEdge FX2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 302 highlights
• tlv: enables traces for DCBX TLVs. Defaults Command Modes Command History none EXEC Privilege Version 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mode only. fcoe-map Create an FCoE map which contains the parameters used to configure the links between server CNAs and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port. Syntax Parameters fcoe-map map-name map-name Maximum: 32 alphanumeric characters. Defaults On the FN2210S Aggregator with PMUX modules, the following parameters are applied on all the PMUX module interfaces: • Description: SAN_FABRIC • Fabric-id: 1002 • Fcoe-vlan: 1002 • Fc-map: 0x0efc00 • Fcf-priority: 128 • Fka-adv-period: 8000mSec • Keepalive: enable • Vlan priority: 3 Command Modes CONFIGURATION INTERFACE Command History Usage Information Version 9.6(0.0) Version 9.3(0.0) Supported on the FN2210S Aggregator with the PMUX module. Introduced on the M I/O Aggregator with the PMUX module. An FCoE map is a template used to map FCoE and FC parameters in a converged fabric. An FCoE map is used to virtualize upstream FC ports on an FN2210S Aggregator with the PMUX module NPIV proxy gateway so that they appear to downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE network. When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map allows the switch to operate as an FCoE-FC bridge between an FC SAN and an 302