Dell PowerEdge FX2 Dell PowerEdge FN I/O Aggregator Command Line Reference Gui - Page 64
show inventory, Example, thermal, sensor, Syntax, Parameters, media, Defaults, Command, Modes, History
View all Dell PowerEdge FX2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
Example (thermalsensor) * Management Unit Dell#show environment thermal-sensor -- Thermal Sensor Readings (deg C) -- Unit Sensor0 Sensor1 Sensor2 0 55 45 58 Dell# show inventory Display the switch type, components (including media), and Dell Networking OS version including hardware identification numbers and configured protocols. Syntax Parameters show inventory [media slot] media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member you want to display pluggable media inventory. Defaults Command Modes Command History Usage Information Example none EXEC Version 9.4(0.0) Supported on the FN I/O aggregator. If there are no fiber ports in the unit, just the header under show inventory media displays. If there are fiber ports but no optics inserted, the output displays "Media not present or accessible". Dell#show inventory System Type System Mode Software Version : PE-FN-410S-IOA : 1.0 : 1-0(0-1859) Unit Type Serial Number Part Number Rev Piece Part ID Rev Svc Tag Exprs Svc Code * 0 PowerEdge-FN-410S-IOA TW000000000020 07NVPVX01 X01 TW-07NVPV-00000-000-0020 X01 N/A N/A * - Management Unit Software Protocol Configured DCBX FIP Snooping IGMP 64