HP Visualize J5000 hp Visualize J5000, J7000 workstations service handbook (a4 - Page 105
DDS-3 Tape Drive Optional, Removing a DDS-3 Tape Drive, Front Panel Screws
View all HP Visualize J5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
Field Replaceable Units (FRUs) FRU Removal and Replacement DDS-3 Tape Drive (Optional) This subsection describes how to remove and replace the optional DDS-3 tape drive. NOTE The bracket assembly and drive bay may be used for either one DDS-3 tape drive, or one floppy disk drive. Removing a DDS-3 Tape Drive: 1. Remove the front panel bezel from the workstation. 2. Remove the two T-15 Torx screws securing the DDS-3 tape drive to the front panel of the workstation chassis. Figure 4-12. Front Panel Screws T-15 Torx screw T-15 Torx screw 3. Slide the DDS-3 tape/floppy disk drive bracket assembly out of the chassis guide rails. Disconnect the the power and ribbon cables from the DDS-3 tape drive. 4. To remove the DDS-3 tape drive from the bracket, remove the four T-10 Torx screws (two on each side) securing the DDS-3 tape drive to the bracket. Replacing a DDS-3 Tape Drive: NOTE See "DDS-3 Tape Drive (Optional) Configuration" on page 38 for information about configuring a DDS-3 tape drive for installation. 1. Remove the front panel bezel and the top panel from the workstation. 2. In the top, left front of the workstation above the DDS-3/floppy disk drive bay, remove the EMI (electromagnetic interference) cover. Chapter 4 101